Commercial/Institutional

Aldo Leopold Legacy Center

dot Case Study Metrics

dot Climate Analysis

dot Site Analysis/Site Design

dot Building Massing and Orientation

dot Envelope Design

dot Illumination

dot Fresh Air - Natural and Mechanical Ventilation

dot Heating - Passive Solar and Mechanical Strategies

dot Cooling - Passive and Mechanical Strategies

dot Renewable Energy

dot Embodied Energy

dot Water and Waste

dot Integration Studies

dot Drawings and Images

dash EpiCenter Artists for Humanity

dash Integrated Design Associates

dash Global Ecology Center

dash Kitsap SEED

Sidwell Friends Middle School

Housing

dash Denny Park Apartments

EcoMOD: OUTin House

dash EcoMOD3: Seam

Lopez Affordable Housing

Wild Sage Cohousing

 

arrow Carbon Neutral Teaching

arrow Resources

arrow Links

 
Carbon Neutral Case Studies
Aldo Leopold Legacy Center, Baraboo, Wisconsin
Envelope Design - Apertures, Shading, Thermal Performance

Envelope - Thermal Enclosure:

Source: High Performance Buildings Database

A highly efficient building envelope reduces thermal transfer. The use of structural insulated panels in place of frame construction greatly increased the insulation value of the walls. Overall, insulation values for almost every part of the building envelope are at least twice the values required by state code. For cold climate buildings this is emerging as a starting point for building envelope design standards. It does pose some challenges in the detailing of the envelope - but which can be accomodated.

Wall Types

Wall Types

Wall Diagram

Diagram Showing the Location of the Various Exterior Wall Types

 

Building Section - Thermal Enclosure:

Leopold Envelope Design

Cross Section of the Aldo Leopold Center showing the
Super Insulated Envelope and Window Detailing

 

Aldo Leopold Center Envelope Design

Cross Section of the Aldo Leopold Center showing the
Integration of the Heating System

Building Envelope - Aperture Distribution:

Building Glazing Ratios per GSF

South 4.3%
East 2.2%
North 3.9%
West 2.2%
Sloped 0.0%
Horizontal 0.0%
TOTAL 12.6%

Operable Window Area per conditioned s.f. 16.1%

Aperture Distribution

Aperture Distribution

Envelope - Controlling Aperture Solar Gains: SOUTH ELEVATION
SOUTH GLAZING
Staff Lunchroom Clerestory and Window Wall Solar Radiation

With passive design, and CND strategies for load reduction, it is extremely important to prevent solar gain into the interior of the building in the cooling months. The windows that allow for passive solar gain in the heating months must be blocked from the exterior to minimize cooling requirements in the summer season. The diagram below shows the way that they roof overhangs have been designed to produce shading during the hot summer months, while at the same time allowing deep solar penetration in the winter. This simple natural extension of the roof also assisted in simplifying the design and saving money that might have otherwise been required if specialized shading devices had been required.

Shading and Overhangs

Basic Shading Strategies for the Two Primary Window Types on the South Elevation

 

Controlling Solar Gain - Transmission Study

Chart

Key

Solar Graphs

Transmission Data for South Facing Windows

Envelope - Controlling Aperture Solar Gains: NORTH ELEVATION
NORTH GLAZING
Clerestory and Office Windows

Although potentially less of an issue in terms of solar control than south facing windows, north facing windows have their own special concerns in Carbon Neutral Design. In the case of the Leopold Center, the windows are being used for daylighting, in order to reduce the electric lighting load during the daytime hours, as well as to promote natural ventilation. From a thermal perspective, windows are significantly less efficient than the super insulated walls that they puncture. So a balance needs to be struck between keeping them large enough to daylight and ventilate the building, but small enough so that they do not result in large winter and nighttime heat losses.

North Glazing

Basic Strategies for the Two Primary Window Types on the North Elevation

Controlling Solar Gain - Transmission Study

North Window Charts

Data

 

   

 

©2012 American Institute of Architects | Society of Building Science Educators | Legal Disclaimer